Bob La Londe <none@none.com99> writes:

> In my process of adding an EV charging station I had wanted to add
> another 20 amp 220V outlet for occasional use of other 220V equipment
> in the garage.  (band saw, radial arm saw, non business CNC machine,
> etc) With the 50 amp breaker for the charging station the sub panel is
> now full.  They make high density breakers (4 poles in the space of
> 2), but I was unable to find one for this panel.
>
> ...

Similar-ish thought about outbuilding here (UK - 230V).  If want it on
a line protected with a time-delayed higher fault current Residual
Current Device - so the RCD in the outbuilding would trip first but
the cable from the house to the outbuilding is still sufficiently
protected - then could have a separate
single-isolator/single-RCD/single-MCB
[MCB == Miniature Circuit Breaker]
box having power coming off the make distribution board just after its
incoming isolator.

You`d be adding a third Residual Current Device in the "Consumer Unit"
(distribution board)
* each RCD takes up two spaces on the rail - takes up space
* another live and neutral cable from isolator to "special" RCD

so separate box suggested as most elegant solution.




--- Gnus/5.11 (Gnus v5.11) Emacs/22.1 (darwin)
 * Origin: BWH Usenet (https://usenet.blueworldhosting.com) (2:5075/128)
SEEN-BY: 5001/100 5005/49 5015/255 5019/40 5020/715
848 1042 4441 12000
SEEN-BY: 5030/49 1081 5058/104 5075/128
@PATH: 5075/128 5020/1042 4441



   GoldED+ VK   │                                                 │   09:55:30    
                                                                                
В этой области больше нет сообщений.

Остаться здесь
Перейти к списку сообщений
Перейти к списку эх