On 9/28/2023 2:11 AM, Richard Smith wrote:
> Bob La Londe <none@none.com99> writes:

>> In my process of adding an EV charging station I had wanted to add
>> another 20 amp 220V outlet for occasional use of other 220V equipment
>> in the garage.  (band saw, radial arm saw, non business CNC machine,
>> etc) With the 50 amp breaker for the charging station the sub panel is
>> now full.  They make high density breakers (4 poles in the space of
>> 2), but I was unable to find one for this panel.
>>
>> ...

> Similar-ish thought about outbuilding here (UK - 230V).  If want it on
> a line protected with a time-delayed higher fault current Residual
> Current Device - so the RCD in the outbuilding would trip first but
> the cable from the house to the outbuilding is still sufficiently
> protected - then could have a separate
> single-isolator/single-RCD/single-MCB
> [MCB == Miniature Circuit Breaker]
> box having power coming off the make distribution board just after its
> incoming isolator.

> You`d be adding a third Residual Current Device in the "Consumer Unit"
> (distribution board)
> * each RCD takes up two spaces on the rail - takes up space
> * another live and neutral cable from isolator to "special" RCD

> so separate box suggested as most elegant solution.






Its my understanding in the UK you have a simpler single voltage 220V 
(nominal) service for residential and non-industrial.

In the US residential and non-industrial is usually split phase.  We 
have a single phase coming in, but its got a half tap at the service 
transformer for 120V nominal which is what most small to medium devices 
are designed to work with.  The 120V device can be wire from either leg 
to the half tap or neutral.  It makes for some interesting conversations 
with other do-it-yourselfers.  In the past there were house which only 
received half phase.  That is their service entrance was 120V nominal 
only.

I may not have the terms exactly right, but that`s the gist of it.  Like 
I said, it makes wiring in extra stuff interesting.


-- 
Bob La Londe
CNC Molds N Stuff


-- 
This email has been checked for viruses by AVG antivirus software.
www.avg.com
 --- Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.15.1
 * Origin: A noiseless patient Spider (2:5075/128)
SEEN-BY: 5001/100 5005/49 5015/255 5019/40 5020/715
848 1042 4441 12000
SEEN-BY: 5030/49 1081 5058/104 5075/128
@PATH: 5075/128 5020/1042 4441



   GoldED+ VK   │                                                 │   09:55:30    
                                                                                
В этой области больше нет сообщений.

Остаться здесь
Перейти к списку сообщений
Перейти к списку эх