On Monday, October 13, 2003 at 1:30:37 PM UTC-5, N2EY wrote:
> In article zw4...@nwrdny01.gnilink.net>, Edward Knobloch
> <al...@nowhere.com> writes:
> >The 5R4 has a maximum piv voltage of 2800 volts,
> >so you would still need 3 1N4007`s in series
> >in each leg for equivalent safety factor.
> Absolutely correct.
> >
> >The rated max supply voltage of 750V rms per plate means that
> >you should not use a transformer higher than
> >1500V rms center tapped in a full wave single phase
> >rectifier circuit using a 5R4.
> The 750 volt rating is for capacitor input. With choke input you can go a bit
> higher.
> >
> >The designers expected switching transients
> >when the current is interrupted in the HV transformer
> >and HV choke, and therefore included a max
> >supply voltage for guidance.
> Even with no transients, the peak voltages that the diodes have to withstand
> are quite high, compared to the RMS transformer voltages. Here`s why:
> First off, the voltages in the transformer catalogs and tube manuals are RMS
> values, not peak values. 750 volts RMS equates to 1060 volts peak with sine
> waves. So under perfect conditions a 750-0-750 (1500VCT) transformer with
> fullwave center tap rectifier and capacitor input filter can have voltage
> output of 1060 volts.
> But there`s more! In our 750-0-750 example, each transformer HV lead goes from
> 1060 volts (peak) positive to 1060 volts negative with respect to the center
> tap. So each diode is subjected to as much as 2120 volts when it is in the
> nonconducting (inverse) state. So you need *at least* three 1N4007s to replace
> one side of a 5R4. Four diodes won`t hurt a thing.
> The tube manuals I have show voltages higher than 750 for capacitor input, but
> they are for the 5R4GYA. 
> In any event please use at least three and preferably four 1N4007s or
> equivalents in a 5R4 replacement. Plate transformers and filter chokes can be
> expensive and hard to replace.
> 73 de Jim, N2EY

 Jim, N2EY is correct in his analysis. You have to look at more
than the output voltage - you need to actually know the circuit analysis
to see the PIV on the diode. His method is exactly right. In many
tube audio amps, two 1000 V PIV (like iN4007) series diodes in each
string is enough. But above 200-300 V, in order to fully match the tube
specs, like one needs a bit more than three. Never use one per side.

 But that`s not all. When you put diodes in series, the reverse
voltages don`t divide equally because each has a different leakage current.
If those are not well matched, one should use "equalizing resistors"
across each diode of about 5 to 10x the leakage current of the diodes.

 Then there transients to consider, and good derating practices. All
this is why the commercial SS replacement plug-ins so frequently fail.
Most guys making them are not engineers and didn`t "do the math".

I personally use two BY2000 2000 V PIV diodes.

Drew K3PA

--- G2/1.0
 * Origin: usenet.network (2:5075/128)
SEEN-BY: 5005/49 5015/255 5019/40 5020/715 848 1042
4441 12000 5030/49 1081
SEEN-BY: 5058/104 5075/128
@PATH: 5075/128 5020/1042 4441



   GoldED+ VK   │                                                 │   09:55:30    
                                                                                
В этой области больше нет сообщений.

Остаться здесь
Перейти к списку сообщений
Перейти к списку эх