Leon <lcb11211@swbell.net> writes:
> YES!  I thought it was more like a bird chirp.

I feel for the bird`s pain then...

https://www.delorie.com/tmp/compressor-squeek.mp4

I cut out most of the middle parts, but it includes the startup and shutdown.

> Another thought, 240 volt motors tend to start with a jolt if properly
> wired, because of less voltage drop.  Have you recently changed the
> voltage for the motor?

Nope, it`s been 240 since I installed it ages ago.