On 7/12/2023 6:47 PM, DJ Delorie wrote:

> So my big shop compressor has two problems.

> First, when it starts, it starts suddenly.  Enough to startle whoever`s
> in the shop, which is not just annoying but dangerous.

> Second, when it starts, it`s now making a squeak sound for a moment as
> well as the expected noises.  I mean, a LOUD squeak, like it`s trying to
> rip the pulleys off. (oil level is fine)

> So I might as well address both problems at the same time.

> The usual litany of questions follows...

> Has anyone experienced a loud squeak at compressor startup?  I assume
> I`ll be disassembling the whole drive chain and inspecting everything,
> but I might as well have something to look for.

YES!  I thought it was more like a bird chirp.  The issue was the reed 
valve plate gasket failed.   The reed valve has a self adhered gasket, 
meaning on mine, the gasket and reed valve had to be replaced as a unit. 
  Relatively inexpensive.

If that leak is significant the squeak could possibly be continuous and 
or result in total compression loss of that particular 
cylinder/cylinders.  A motor may start much more quickly if there is 
less or no resistance.

Another thought, the pressure relief valve is not closing after the 
pressure is released at shut down.  If it remains open there will be a 
lot less resistance on the motor.  It makes that short hiss when the 
motor shuts down.  If that valve remains open the motor will go to top 
speed almost instantly.  It should only remain open for a brief moment 
until the motor begins to spin.


> Has anyone tried to soft-start a compressor?  I`ve added hard-start kits
> to motors before to avoid current spikes, but nothing designed to ramp
> up the speed itself.  Is switching to three phase and adding a VFD to
> ramp up the speed overkill, or even possible?

Another thought, 240 volt motors tend to start with a jolt if properly 
wired, because of less voltage drop.   Have you recently changed the 
voltage for the motor?

 --- Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.13.0
 * Origin: usenet.network (2:5075/128)
SEEN-BY: 5001/100 5005/49 5015/255 5019/40 5020/715
848 1042 4441 12000
SEEN-BY: 5030/49 1081 5058/104 5075/128
@PATH: 5075/128 5020/1042 4441



   GoldED+ VK   │                                                 │   09:55:30    
                                                                                
В этой области больше нет сообщений.

Остаться здесь
Перейти к списку сообщений
Перейти к списку эх